Observation
Technology that Reveals What Couldn’t Be Seen Before
Dedicated Field Lenses Make High-Grade Imaging Simple
Manufactured specifically for the DSX110, dedicated 1X, 3.6X, and 10X lenses combine high NA, long working distances, wellcontrolled aberration, and evenness of light
intensity like never before.
Zoom Optics Cover a Wide Range of Magnification
Wide Zoom and Magnification Range: Get Closer to the Sample
The DSX110 provides an optical zoom up to 16X and a digital zoom up to 30X. The DSX110 also offers a wide magnification range, with a 16X wide zoom range,
and a total magnification of 7X to 1071X (with dedicated 10X lens).
Free-Angle Function: Angled Viewing with No Need to Touch the Sample
With the free-angle function of DSX110, merely tilt the zoom head to change the viewing angle without touching the sample. A sturdy frame with a low center
of gravity provides extra stability when tilting the head.
A Variety of Observation Methods, Freely Usable
Flexible LED Ring Light Makes Scratches and Defects Easy to See
The LED ring light of DSX110 is divided into four segments that allow flexible illumination control, making scratches and defects easy to find and identify.
Polarized Lighting Controls LED Unit Reflection
When observing highly reflective samples, the polarized lighting of DSX110 controls reflection of the LED illumination ring, ensuring clear observation.
Advanced Image Processing
HDR: High-Definition Visuals Beyond the Human Eye
Sample appearance can vary depending on quality of material, surface conditions, or illumination methods. One of a variety of observation methods made possible
by the advanced digital technology of DSX110, the HDR (High Dynamic Range) function, combines several images taken at different exposures to accurately correct brightness
differences on the sample surface, delivering a more consistently accurate sample rendition.
Anyone Can Make Observations in Optimum Conditions
Best Image Function Ensures Optimal Performance from Any Operator
The DSX110 will set all the necessary parameters to achieve that image. The Best image function ensures optimal images, whether looking for defects,
uneven surfaces, or foreign objects. With Best image, anyone can operate the system — beginner to expert — and it can be customized for each operator.
Capturing
Capture Full-Focus Images or 3D Images
EFI: View Uneven Samples in Focus Across the Entire Image
With its EFI (Extended Focal Image) capability, the DSX110 can obtain a clear, in-focus image of an entire sample with one click — no matter how uneven the surface. During EFI,
several images are taken while the point of focus is moved up and down. From these images, the areas where the sample was in focus are combined into one image where the
whole sample is in focus, allowing precise inspection of uneven surfaces. Olympus’s EFI capturing speed is now faster than ever.
3D Image: One Click Shows the Sample in 3D
With one click, the DSX110 can capture image samples in three dimensions, allowing examination from any angle and a view of the sample as it actually is. With detailed 3D
images, sample features or unevenness can be viewed and measured. Height differences and volume can also be measured, making it easier to accurately analyze the sample.
*Requires 3.6X or 10x objective lens for 3D image capturing
Live Panorama Capturing Covers Large Areas Fast
There is no longer such a problem as “outside the field of view.” With Live panorama, simply move the observation position on the screen, and the motorized stage will move the
sample to that position. As the stage moves, the system automatically stitches images into a large single field of view, in real time.
Auto Panorama: One Click Captures a Large Field of View
Simply put the sample on the stage, and start the process with one click. The stage moves in a spiral and the feature captures the required area automatically.
Automatic Stitching Gives High Quality, High Value-Added Image
High Quality Panorama
Set the number of images, the length, and the starting point, then start the image stitching process. This executes pattern matching and corrects shading,
resulting in a high-quality and high value-added image.
EFI and 3D Image Capturing
High quality panorama capability can be coordinated with EFI and 3D image capturing as well. The ability to capture images across a wide area, show uneven surfaces in full focus,
and produce 3D images means the data exceeds that of ordinary digital microscopes.
Large Amounts of Data Automatically Captured
Programmed Recipes: Automatically Capture Independent Points
Through a convenient programmed recipe function, the DSX110 can automatically capture images of several registered points using its autofocus function.
Measurement
Ample Measurement Functions
The Features Required to Ensure Optimal Measurement Results
All fundamental industrial microscope measurement capabilities are standard features of DSX110 software, making it easy to obtain optimal measurement results.
Optional software is available for 3D measurement, caliper measurement, and particle analysis.
Sharing
100% of All Data Can Be Shared
Custom Report Generation Made Easy
With the DSX110, it’s easy. Operators concentrate on image capture, observation, and measurement, and the DSX110 automatically generates the relevant reports. Report templates are fully customizable.
사양
DSX110 Specifications
Main frame |
Zoom ratio |
Optical zoom |
DSXPLFL3.6X/1X: 1X to 16X (max) XLMPLFLN10XDSX (with DSX-LEDAD10X): 4X to 16X (max) |
Digital zoom |
17X to 30X |
Mountable objective lens |
DSX dedicated objective lens |
DSXPLFL1X, DSXPLFL3.6X, XLMPLFLN10XDSX+DSX-LEDAD10X |
Illumination (Objective lens) |
LED ring light illumination |
Camera |
Image sensor |
1/1.8 inch, 2.01 megapixels, color CCD (total pixels: 2.10 megapixels) Total pixels : 1688 (H) x 1248 (V)
Available pixels : 1628 (H) x 1236 (V) Effective pixels : 1600 (H) x 1200 (V) |
Cooling method |
Peltier cooling |
Scan mode |
Progressive scan |
Frame rate |
15 fps/27 fps with binning mode |
Image size |
Normal : 1194 x 1194 (1:1)/1592 x 1194 (4:3) Fine : 1194 x 1194 (1:1)/1592 x 1194 (4:3) Super fine : 3594 x 3594 (1:1)/4792 x 3594 (4:3) |
Sensitivity |
ISO 100/200/400/800/1600 equivalent |
Fine focusing (Motorized) |
Stroke |
34 mm |
Resolution |
0.4 μm |
Frame |
Coarse focusing (Manual) |
Stroke |
50 mm |
Maximum sample height |
Standard |
80 mm*1 |
To ensure U-centric operation in tilted operation |
50 mm*2 |
Tilt mechanism |
Type |
Manual, lock/release handle |
Tilt angle |
Left/Right 45° |
Stage |
DSX-UFSSU (Motorized)*3 |
Stroke |
100 x 100 mm |
Load capacity |
1 kg |
U-SIC4R2 (Manual) |
Stroke |
100 x 105 mm |
Load capacity |
1 kg |
LCD monitor |
Size |
23” with touch panel and Full HD color LCD monitor |
Resolution |
1920 (H) x 1080 (V) |
Weight |
(Main frame, Manual stage, LCD monitor, Control box, Controller) |
Approx. 36.5 kg |
Input rating |
100-120 V/220-240 V, 300 V A, 50/60 Hz |
*1 50 mm in case of the combination with DSX-UFSSU (not included BH2-WHR43/wafer holder plate)
*2 20 mm in case of the combination with DSX-UFSSU (not included BH2-WHR43/wafer holder plate) *3 DSX-WZ-STAD is required to install
DSX110 Objective Lens
Series |
Model |
Parfocal distance |
NA |
W.D. (mm) |
Actual F.O.V. (μm)*1 |
Total magnification*2 |
DSX dedicated objective lens |
DSXPLFL1X |
167 mm |
0.025 |
138*3 |
57,447-3,591 |
7X-107X |
DSXPLFL3.6X |
79 mm |
0.09 |
50*4 |
15,958-997 |
24X-386X |
XLMPLFLN10XDSX + DSX-LEDAD10X |
79 mm |
0.27 |
30 |
1,437-359 |
268X-1,071X |
*1 At aspect ratio 1:1 diagonal (with factory default value) *2 At aspect ratio 1:1 *3 123 mm in case of the combination with the DSX-POAD1X *4 35 mm in case of the combination with the DSX-POAD3.6X
|